- LF909 Large Lead Free Reduced Pressure Zone Assembly Backflow Preventer with Flood Sensor

LF909 Large Lead Free Reduced Pressure Zone Assembly Backflow Preventer with Flood Sensor
Series LF909 Large Lead Free* Reduced Pressure Zone assemblies feature a flood sensor utilizing SentryPlus Alert® technology to detect continuous discharge from the relief valve. When paired with an add-on connection kit, the sensor relays alerts for potential flooding events via BMS, cellular communication, or the Sensor Control Monitor (BAS via RS-485 Modbus or Nexa® via Wi-Fi). This series prevents the reverse flow of contaminated water caused by backsiphonage or backpressure from entering the potable water supply. Valve internals are protected by ArmorTek®, a multilayer corrosion-resistant coating engineered to extend service life in demanding environments, while its compact modular design facilitates maintenance. • Sensor on the relief valve for flood detection • Integrates with the Sensor Control Monitor to deliver maintenance alerts to BAS via RS-485 Modbus or the Nexa platform by Wi-Fi connectivity • ArmorTek coating technology to resist corrosion of internals • Exclusive relief valve design provides maximum capacity during emergency conditions • Industrial strength sensing hose on larger size models • Can be used in a variety of installations, including containment at the service line entrance • No special tools required for servicing
View on the Manufacturer's SiteTechnical Specifications
| Size Range | 2-1/2 - 10 IN |
|---|---|
| Inlet / Outlet Connection Sizes | 2 1/2 IN, 3 IN, 4 IN, 6 IN, 8 IN, 10 IN |
| Inlet Shutoff Valve Types | No Shutoff Valve, Non Rising Stem Gate Valve, Outside Stem And Yoke Gate Valve, Quarter Turn Ball Valve |
| Technologies | Flood Detection, SentryPlus Alert®, ArmorTek® |
Technical Documents
Documents open from the manufacturer's official site.
Installation, Operation and Maintenance Manuals
- Installation Instructions - 909 Large, LF909 Large, 909RPDAPDF
- Installation Instructions - BMS Flood Sensor Connection KitPDF
- Installation Instructions - BMS Flood Sensor Upgrade - 909, LF909 Large, 909RPDAPDF
- Installation Instructions - Cellular Flood Sensor Connection KitPDF
- Installation Instructions - Cellular Flood Sensor Upgrade - 909, LF909 Large, 909RPDAPDF
- Installation Instructions - Custom Flood Sensor SettingsPDF
- Installation Instructions - Sensor Control MonitorPDF
- Repair Kits Parts Breakdown - 909, LF909 21/2-10 INPDF
- Installation Instructions - SentryPlus Alert Technology - Universal Upgrade Kit (January 2019 - June 2020)PDF
- Installation Instructions - SentryPlus Alert Technology (June 2020 - Oct 2025)PDF
Sales Literature
- Brochure - Backflow Prevention and Flow Control for WaterworksPDF
- Brochure - Backflow Prevention and Flow Control for Waterworks (French)PDF
- Brochure - Backflow Prevention and Flow Control for Waterworks (Spanish)PDF
- Brochure - Backflow Prevention and Flow Control PlumbingPDF
- Brochure - Backflow Prevention and Flow Control Plumbing (French)PDF
- Brochure - Backflow Prevention and Flow Control Plumbing (Spanish)PDF
- Flyer - Flood Detection Connection Kits for 009 and 909 Backflow PreventersPDF
- Flyer - Flood Detection for RPZ/RPDA Backflow Preventers with Flood Sensor (French)PDF
Specifications
- Relief Valve Discharge Rates - 009, 909, 919, 957, 994PDF
- Specification Sheet - Flood Sensor Connection Kit - WattsPDF
- Specification Sheet - Flood Sensor Connection Kit - Watts (Spanish)PDF
- Specification Sheet - LF909 LargePDF
- Specification Sheet - LF909 Large (French)PDF
- Specification Sheet - LF909 Large (Spanish)PDF
- Specification Sheet - NYC Backflow Specialty ItemsPDF
- Specification Sheet - Sensor Control MonitorPDF
- Specification Sheet - Sensor Control Monitor (French)PDF
- Specification Sheet - Sensor Control Monitor (Spanish)PDF
- Specification Sheet - Watts Air Gaps, Elbows and Test CocksPDF
- Specification Sheet - SentryPlus Alert Technology - Universal Upgrade Kit (June 2024 - Oct 2025)PDF
Application Areas
- Protection at health hazard cross-connections
- Containment at the service line entrance
- Potable water supply protection against backsiphonage or backpressure
Frequently Asked Questions
Which connection sizes are available?
Size Range: 2-1/2 - 10 IN.
Where can I find the datasheet and catalogue PDF?
In the "Technical Documents" section on this page; documents open from the manufacturer’s official site.
How do I get a price quote for this product?
Fill in the quote form at the bottom of this page or call +90 322 235 22 35. Gookir Global is the authorized Watts distributor in Turkey.
Quote Request
Get a price quote for this product
Leave your details and our sales team will check quantities, lead time and technical fit, then reply with a tailored quote.
LF909 Large Lead Free Reduced Pressure Zone Assembly Backflow Preventer with Flood Sensor