- Startseite
- Watts
- Rückflussverhinderer
- LF866 Lead Free MasterSeries In-Line Reduced Pressure Zone Detector Assembly Backflow Preventer with Flood Sensor

LF866 Lead Free MasterSeries In-Line Reduced Pressure Zone Detector Assembly Backflow Preventer with Flood Sensor
MasterSeries LF866 Lead Free* reduced pressure detector assemblies feature a flood sensor using SentryPlus Alert® technology to detect continuous discharge from the relief valve. When paired with an add-on connection kit, the sensor is activated to relay alerts for potential flooding events. Connection kit options include BMS, cellular communication, and the Sensor Control Monitor, which enables integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi. This series prevents the reverse flow of fire protection system substances being pumped or siphoned into the potable water supply. An incorporated meter detects ground leaks and unauthorized illegal taps to help reduce annual water expenses. The ductile iron body is fused with ArmorTek®, a patented 3-part advanced epoxy coating system designed to limit microbial induced corrosion (MIC) and exposed metal substrate corrosion. • Sensor on the relief valve for flood detection • Integrates with the Sensor Control Monitor to deliver maintenance alerts to BAS via RS-485 Modbus or the Nexa platform by Wi-Fi connectivity • Utilizes advanced ArmorTek coating technology to build in electrochemical corrosion inhibitor and microbial inhibitor to resist corrosion of internal parts • Combines the use of a stainless-steel relief valve seat and stainless-steel check components for maximum performance and durability • Requires no special tools for inline service • Is highly suitable for potable drinking water systems where code mandates protection from backpressure and backsiphonage conditions • Protects potable water against cross-connection contamination of high hazard (toxic) fluids in water services • Sizes 2 1/2 to 10 Inch
Auf der Herstellerseite ansehenTechnische Daten
| Product Line | FEBCO |
|---|---|
| Size Range | 2 1/2 to 10 IN (2 1/2, 3, 4, 6, 8, 10 IN) |
| Body Material | Ductile Iron with ArmorTek® Coating |
| Inlet and Outlet Connection Sizes | 2 1/2 IN, 3 IN, 4 IN, 6 IN, 8 IN, 10 IN |
| Inlet Shutoff Valve Type | No Shutoff Valve, Outside Stem And Yoke Gate Valve |
| Internal Components Material | Stainless Steel Relief Valve Seat and Check Components |
| Flood Sensor Technology | SentryPlus Alert® |
Technische Dokumente
Dokumente werden von der offiziellen Website des Herstellers geöffnet.
Installations-, Betriebs- und Wartungsanleitungen
- Installation Instructions - BMS Flood Sensor Retrofit Connection Kit - LF860 Large, LF866, LF880V, LF886VPDF
- Installation Instructions - Cellular Flood Sensor Retrofit Connection Kit - LF860 Large, LF866, LF880V, LF886VPDF
- Installation Instructions - Custom Flood Sensor SettingsPDF
- Installation Instructions - LF860 Large, LF866PDF
- Installation Instructions - Relief Valve Inner DiaphragmPDF
- Installation Instructions - Sensor Control MonitorPDF
- Maintenance Manual - 860 Large, 880V, LF860 Large, LF866, LF880V, LF886VPDF
Verkaufsunterlagen
- Brochure - ArmorTek Advanced Coating SystemPDF
- Brochure - ArmorTek Advanced Coating System - SpanishPDF
- Brochure - Backflow Prevention and Flow Control for WaterworksPDF
- Brochure - Backflow Prevention and Flow Control for Waterworks (French)PDF
- Brochure - Backflow Prevention and Flow Control for Waterworks (Spanish)PDF
- Brochure - FEBCO MasterSeriesPDF
- Flyer - FEBCO MasterSeries-Type II BypassPDF
- Flyer - Flood Detection for RPZ/RPDA Backflow Preventers with Flood Sensor (French)PDF
- Sell Sheet - Retrofit-Spool Simple Order Form - LF850, LF860, LF856, LF866PDF
Spezifikationen
- Specification Sheet - Flood Sensor Connection Kit - FEBCOPDF
- Specification Sheet - Flood Sensor Connection Kit - FEBCO (French)PDF
- Specification Sheet - Flood Sensor Connection Kit - FEBCO (Spanish)PDF
- Specification Sheet - LF866 (French)PDF
- Specification Sheet - LF866 (Spanish)PDF
- Specification Sheet - Relief Valve Discharge RatesPDF
- Specification Sheet - Sensor Control MonitorPDF
- Specification Sheet - Sensor Control Monitor (French)PDF
- Specification Sheet - Sensor Control Monitor (Spanish)PDF
Anwendungsbereiche
- Fire protection systems
- Potable drinking water systems and water services
Häufig gestellte Fragen
Aus welchem Werkstoff besteht dieses Modell?
Body Material: Ductile Iron with ArmorTek® Coating.
Welche Anschlussgrößen sind erhältlich?
Size Range: 2 1/2 to 10 IN (2 1/2, 3, 4, 6, 8, 10 IN).
Wo finde ich Datenblatt und Katalog als PDF?
Im Abschnitt „Technische Dokumente“ auf dieser Seite; die Dokumente öffnen sich auf der offiziellen Website des Herstellers.
Wie erhalte ich ein Preisangebot für dieses Produkt?
Füllen Sie das Angebotsformular unten auf dieser Seite aus oder rufen Sie +90 322 235 22 35 an. Gookir Global ist Watts-Vertragshändler in der Türkei.
Angebotsanfrage
Preisangebot für dieses Produkt anfordern
Hinterlassen Sie Ihre Kontaktdaten. Unser Vertriebsteam prüft Stückzahlen, Lieferzeiten sowie die technische Eignung und erstellt ein maßgeschneidertes Angebot.
LF866 Lead Free MasterSeries In-Line Reduced Pressure Zone Detector Assembly Backflow Preventer with Flood Sensor
