- Startseite
- Watts
- Rückflussverhinderer
- Ames Deringer 50X/50GX Low Head Loss Reduced Pressure Detector Type II Assembly Backflow Preventers

Ames Deringer 50X/50GX Low Head Loss Reduced Pressure Detector Type II Assembly Backflow Preventers
Ames Deringer™ 50X and 50GX Reduced Pressure Detector Type II Assemblies are designed to prevent non-health hazard pollutants and hazardous contaminants from entering the potable water supply system caused by backpressure and/or backsiphonage conditions. Deringer 50X features integral Eccentric-seal™ butterfly shutoff valves for a short lay length, XL body and checks for lower head loss, and Dual-action™ checks for high performance at low- and high-flow rates. Deringer 50GX has the same features with OS&Y shutoff valves. The Type II bypass is used to monitor unauthorized water usage and is primarily required on fire sprinkler systems. Both models may be installed under continuous pressure service to protect against backpressure and backsiphonage up to a maximum working pressure of 175 psi (12 bar). • XL body and checks for low head loss • Integral shutoffs for shorter lay length and lightweight construction (Deringer 50X only) • Dual-action check module for low- and high-flow performance • Tamper-resistant test cocks • Type II bypass for lower weight and simplified testing
Auf der Herstellerseite ansehenTechnische Daten
| Product Line | Ames Fire & Waterworks |
|---|---|
| Maximum Working Pressure | 175 psi (12 bar) |
| Connection Size | 4 IN, 6 IN |
| Connection Type | Flanged Joint, Grooved Joint |
| Inlet Shutoff Valve Type | Gear Operated Butterfly Valve, Outside Stem And Yoke Gate Valve |
| Technologies | Flood Detection |
Technische Dokumente
Dokumente werden von der offiziellen Website des Herstellers geöffnet.
Installations-, Betriebs- und Wartungsanleitungen
- Maintenance Manual - Deringer Gear Box ReplacementPDF
- Maintenance Manual - Deringer Gear Box WiringPDF
- Maintenance Manual - Deringer Indicator FlagPDF
- Maintenance Manual - Deringer Tamper SwitchPDF
- Maintenance Manual - For Deringer Models 40/50 - Sizes 6 and 8 IN, For Models 40X/50X - Sizes 4 and 6 INPDF
- Maintenance Manual - For Deringer Models 40G/50G - Sizes 6 and 8 IN, For Models 40GX/50GX - Sizes 4 and 6 INPDF
- User Guide - For All Deringer Series ValvesPDF
Verkaufsunterlagen
Anwendungsbereiche
- Fire sprinkler systems
- Potable water supply systems
Häufig gestellte Fragen
Welche Druckstufe hat dieses Modell?
Maximum Working Pressure: 175 psi (12 bar).
Welche Anschlussgrößen sind erhältlich?
Connection Size: 4 IN, 6 IN.
Wo finde ich Datenblatt und Katalog als PDF?
Im Abschnitt „Technische Dokumente“ auf dieser Seite; die Dokumente öffnen sich auf der offiziellen Website des Herstellers.
Wie erhalte ich ein Preisangebot für dieses Produkt?
Füllen Sie das Angebotsformular unten auf dieser Seite aus oder rufen Sie +90 322 235 22 35 an. Gookir Global ist Watts-Vertragshändler in der Türkei.
Angebotsanfrage
Preisangebot für dieses Produkt anfordern
Hinterlassen Sie Ihre Kontaktdaten. Unser Vertriebsteam prüft Stückzahlen, Lieferzeiten sowie die technische Eignung und erstellt ein maßgeschneidertes Angebot.
Ames Deringer 50X/50GX Low Head Loss Reduced Pressure Detector Type II Assembly Backflow Preventers