- Startseite
- Watts
- Rückflussverhinderer
- Ames Deringer 40/40G Reduced Pressure Zone Assembly Backflow Preventers

Ames Deringer 40/40G Reduced Pressure Zone Assembly Backflow Preventers
Ames Deringer™ 40 and 40G Reduced Pressure Zone Assemblies are designed to prevent hazardous contaminants and non-health hazard pollutants from entering the potable water supply system caused by backpressure and/or backsiphonage conditions. Deringer 40 features integral Eccentric-seal™ butterfly shutoff valves for a short lay length, along with True-Seal™ and Dual-action™ checks for high performance at both low- and high-flow rates. Deringer 40G features Dual-action checks with OS&Y shutoff valves. Both models can be installed under continuous pressure service to protect against backpressure and backsiphonage, with a maximum working pressure of 175 psi (12 bar). An optional external flood sensor connection kit is available to detect flowing discharge from the relief valve and signal a flood condition to the building management system via relay. • Integral shutoffs for shorter lay length and lightweight construction (Deringer 40 only) • Bow-seal™ full access cover for lower weight and easy access to valve internals • Dual-action check module for low- and high-flow performance • Optional flood sensor connection kit to detect flowing discharge from the relief valve; provides dry contact output for BMS integration • Tamper-resistant test cocks • Prewired supervisory switches (Deringer 40 only)
Auf der Herstellerseite ansehenTechnische Daten
| Product Line | Ames Fire & Waterworks |
|---|---|
| Maximum Working Pressure | 175 psi (12 bar) |
| Connection Size | 2 1/2 IN, 3 IN, 4 IN, 6 IN, 8 IN |
| Inlet/Outlet Connection Type | Flanged Joint, Grooved Joint |
| Inlet Shutoff Valve Type | Gear Operated Butterfly Valve, Outside Stem And Yoke Gate Valve |
| Technologies | Flood Detection |
Technische Dokumente
Dokumente werden von der offiziellen Website des Herstellers geöffnet.
Installations-, Betriebs- und Wartungsanleitungen
- Maintenance Manual - Deringer Gear Box ReplacementPDF
- Maintenance Manual - Deringer Gear Box WiringPDF
- Maintenance Manual - Deringer Indicator FlagPDF
- Maintenance Manual - Deringer Tamper SwitchPDF
- Maintenance Manual - For Deringer Models 40/50 - Sizes 6 and 8 IN, For Models 40X/50X - Sizes 4 and 6 INPDF
- Maintenance Manual - For Deringer Models 40/50 Only - Sizes 2 1/2-4 INPDF
- Maintenance Manual - For Deringer Models 40G/50G - Sizes 6 and 8 IN, For Models 40GX/50GX - Sizes 4 and 6 INPDF
- Maintenance Manual - For Deringer Models 40G/50G Only - Sizes 2 1/2-4 INPDF
- User Guide - For All Deringer Series ValvesPDF
Verkaufsunterlagen
Anwendungsbereiche
- Potable water supply systems
Häufig gestellte Fragen
Welche Druckstufe hat dieses Modell?
Maximum Working Pressure: 175 psi (12 bar).
Welche Anschlussgrößen sind erhältlich?
Connection Size: 2 1/2 IN, 3 IN, 4 IN, 6 IN, 8 IN.
Wo finde ich Datenblatt und Katalog als PDF?
Im Abschnitt „Technische Dokumente“ auf dieser Seite; die Dokumente öffnen sich auf der offiziellen Website des Herstellers.
Wie erhalte ich ein Preisangebot für dieses Produkt?
Füllen Sie das Angebotsformular unten auf dieser Seite aus oder rufen Sie +90 322 235 22 35 an. Gookir Global ist Watts-Vertragshändler in der Türkei.
Angebotsanfrage
Preisangebot für dieses Produkt anfordern
Hinterlassen Sie Ihre Kontaktdaten. Unser Vertriebsteam prüft Stückzahlen, Lieferzeiten sowie die technische Eignung und erstellt ein maßgeschneidertes Angebot.
Ames Deringer 40/40G Reduced Pressure Zone Assembly Backflow Preventers